<LOGO>
FM Transmitter Measurement Report
Created: 2024-12-29 07-51-31
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 4/5, 51 dBuV VOLTAGE
Pilot RDS Phase Difference
7.1 kHz 3.6 kHz 22 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
12 kHz 73 kHz 6819 61,2113
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
7,0 dBr 7,68 dBr 8,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 10 (Pop M) 1 0 0 5 7:51, 29.12.2024
RT
"VOLTAGE - Dance music "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 4/5 (51 dBuV) Max at: 73 kHz MIN: 12 kHz % above 75 kHz: 61,2113 Acquired: 2024/12/29 7:50:27 Total samples: 6819 Equivalent time: 0:05:40 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 8,3 dBr MIN: 7,0 dBr AVE: 7,68 dBr % above 10,0 dBr: 0,0 Last value: 7,2 dBr (2024/12/29 7:50:26) Station: 96.90 MHz, signal: 4/5 (52 dBuV) 07:44 07:45 07:46 07:47 07:48 07:49 07:50 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality